  1. Corrosion

    1. Which form of corrosion produces deep, localised holes?

    • A. Chalking
    • B. Pitting
    • C. Uniform corrosion
    • D. Mud cracking
    Show answer

    Answer: B. Pitting

    Pitting can perforate a wall with little overall metal loss.

  2. Coatings

    2. Two-pack epoxies and polyurethanes cure by

    • A. oxidation only
    • B. chemical reaction between base and curing agent
    • C. sunlight only
    • D. solvent evaporation only
    Show answer

    Answer: B. chemical reaction between base and curing agent

    Mixing ratio and pot life must be respected.

  3. Calculations

    3. A coating has 70% volume solids. What wet film thickness gives a dry film of 200 µm (no thinner)?

    • A. 140 µm
    • B. 400 µm
    • C. 270 µm
    • D. 286 µm
    Show answer

    Answer: D. 286 µm

    WFT = DFT × 100 ÷ VS = 200 × 100 ÷ 70 = 286 µm.

  4. Surface prep

    4. Which test checks compressed air for oil and water before blasting?

    • A. Blotter test (ASTM D4285)
    • B. Pull-off test
    • C. Holiday test
    • D. Bresle test
    Show answer

    Answer: A. Blotter test (ASTM D4285)

    Contaminated air puts oil on the steel.

  5. Calculations

    5. A coating has 60% volume solids and is specified at 100 µm DFT. What is the theoretical spreading rate? (m²/L = VS% × 10 ÷ DFT µm)

    • A. 7 m²/L
    • B. 3 m²/L
    • C. 6 m²/L
    • D. 60 m²/L
    Show answer

    Answer: C. 6 m²/L

    60 × 10 ÷ 100 = 6 m²/L.

  6. Failures

    6. Osmotic blistering is mainly caused by

    • A. low humidity
    • B. soluble salts left under the coating
    • C. too thin a primer only
    • D. sunlight
    Show answer

    Answer: B. soluble salts left under the coating

    Water is drawn through the film towards the salts.

  7. Calculations

    7. A 60% volume solids paint is thinned by 5%. What WFT gives 125 µm DFT? (WFT = DFT × (100 + thinner%) ÷ VS)

    • A. 208 µm
    • B. 71 µm
    • C. 219 µm
    • D. 198 µm
    Show answer

    Answer: C. 219 µm

    125 × (100 + 5) ÷ 60 = 219 µm.

  8. Calculations

    8. The dew point is 20 °C and the steel surface is 24 °C. Can coating go ahead (using the 3 °C rule)?

    • A. Only if relative humidity is 100%
    • B. No — the steel is less than 3 °C above the dew point
    • C. Yes — the steel is at least 3 °C above the dew point
    • D. Dew point does not matter for coating
    Show answer

    Answer: C. Yes — the steel is at least 3 °C above the dew point

    The margin is 4 °C; at least 3 °C is required.

  9. Coatings

    9. A zinc-rich primer protects steel mainly by

    • A. sacrificial (galvanic) protection
    • B. inhibitive pigments only
    • C. adding heat
    • D. barrier action only
    Show answer

    Answer: A. sacrificial (galvanic) protection

    Barrier coatings block water and oxygen; inhibitive coatings slow corrosion chemically.

  10. Defects

    10. Mud cracking is usually caused by

    • A. using the wrong colour
    • B. applying it too thin
    • C. cold steel only
    • D. applying the coating too thick
    Show answer

    Answer: D. applying the coating too thick

    Common with zinc-rich primers.