  1. Core

    1. The stratospheric ozone layer protects Earth from

    • A. visible light
    • B. harmful ultraviolet (UV-B) radiation
    • C. infrared heat
    • D. radio waves
    Show answer

    Answer: B. harmful ultraviolet (UV-B) radiation

    Depletion increases skin cancer and cataracts.

  2. Records

    2. Technicians and owners should keep refrigerant service records for at least

    • A. 10 years
    • B. 1 year
    • C. 30 days
    • D. 3 years
    Show answer

    Answer: D. 3 years

    Recordkeeping requirements apply to many appliances.

  3. Core

    3. The international treaty that phases out ozone-depleting substances is the

    • A. Kyoto Protocol
    • B. Montreal Protocol
    • C. Paris Agreement
    • D. Geneva Convention
    Show answer

    Answer: B. Montreal Protocol

    It was signed in 1987.

  4. Core

    4. Compared with R-22, R-410A operates at

    • A. the same pressures
    • B. below atmospheric pressure
    • C. lower pressures
    • D. much higher pressures
    Show answer

    Answer: D. much higher pressures

    Use gauges and hoses rated for R-410A.

  5. Core

    5. Refrigerant blends with temperature glide (zeotropic blends such as R-407C) should be charged

    • A. as either, it makes no difference
    • B. only by weight of vapor
    • C. as a vapor
    • D. as a liquid
    Show answer

    Answer: D. as a liquid

    Charging as vapor can change the blend composition (fractionation).

  6. Safety

    6. ASHRAE Standard 15 requires machinery rooms to have

    • A. windows only
    • B. no ventilation
    • C. open flames for heating
    • D. refrigerant sensors and alarms
    Show answer

    Answer: D. refrigerant sensors and alarms

    Some refrigerants can displace oxygen.

  7. Core

    7. ASHRAE Standard 34 safety group A1 means a refrigerant has

    • A. is banned
    • B. high flammability
    • C. lower toxicity and no flame propagation
    • D. high toxicity
    Show answer

    Answer: C. lower toxicity and no flame propagation

    B is higher toxicity; 2 and 3 indicate flammability.

  8. Core

    8. Which refrigerants have the highest ozone depletion potential?

    • A. CFCs (such as R-12)
    • B. natural refrigerants like CO₂
    • C. HFCs (such as R-134a)
    • D. HFOs
    Show answer

    Answer: A. CFCs (such as R-12)

    HCFCs (such as R-22) have lower ODP; HFCs have none.

  9. Type III

    9. Low-pressure chillers use a purge unit to

    • A. increase pressure
    • B. remove oil
    • C. add refrigerant
    • D. remove air and moisture (non-condensables) that leak in
    Show answer

    Answer: D. remove air and moisture (non-condensables) that leak in

    Excessive purging can indicate a leak.

  10. Safety

    10. When handling refrigerant, you should wear

    • A. only a dust mask
    • B. safety glasses and gloves
    • C. nothing special
    • D. sandals
    Show answer

    Answer: B. safety glasses and gloves