EPA 608 EPA 608 refrigerants practice questions
10 free questions with answers and explanations. Try each one, then tap “Show answer”.
- Core
1. The stratospheric ozone layer protects Earth from
- A. visible light
- B. harmful ultraviolet (UV-B) radiation
- C. infrared heat
- D. radio waves
Show answer
Answer: B. harmful ultraviolet (UV-B) radiation
Depletion increases skin cancer and cataracts.
- Records
2. Technicians and owners should keep refrigerant service records for at least
- A. 10 years
- B. 1 year
- C. 30 days
- D. 3 years
Show answer
Answer: D. 3 years
Recordkeeping requirements apply to many appliances.
- Core
3. The international treaty that phases out ozone-depleting substances is the
- A. Kyoto Protocol
- B. Montreal Protocol
- C. Paris Agreement
- D. Geneva Convention
Show answer
Answer: B. Montreal Protocol
It was signed in 1987.
- Core
4. Compared with R-22, R-410A operates at
- A. the same pressures
- B. below atmospheric pressure
- C. lower pressures
- D. much higher pressures
Show answer
Answer: D. much higher pressures
Use gauges and hoses rated for R-410A.
- Core
5. Refrigerant blends with temperature glide (zeotropic blends such as R-407C) should be charged
- A. as either, it makes no difference
- B. only by weight of vapor
- C. as a vapor
- D. as a liquid
Show answer
Answer: D. as a liquid
Charging as vapor can change the blend composition (fractionation).
- Safety
6. ASHRAE Standard 15 requires machinery rooms to have
- A. windows only
- B. no ventilation
- C. open flames for heating
- D. refrigerant sensors and alarms
Show answer
Answer: D. refrigerant sensors and alarms
Some refrigerants can displace oxygen.
- Core
7. ASHRAE Standard 34 safety group A1 means a refrigerant has
- A. is banned
- B. high flammability
- C. lower toxicity and no flame propagation
- D. high toxicity
Show answer
Answer: C. lower toxicity and no flame propagation
B is higher toxicity; 2 and 3 indicate flammability.
- Core
8. Which refrigerants have the highest ozone depletion potential?
- A. CFCs (such as R-12)
- B. natural refrigerants like CO₂
- C. HFCs (such as R-134a)
- D. HFOs
Show answer
Answer: A. CFCs (such as R-12)
HCFCs (such as R-22) have lower ODP; HFCs have none.
- Type III
9. Low-pressure chillers use a purge unit to
- A. increase pressure
- B. remove oil
- C. add refrigerant
- D. remove air and moisture (non-condensables) that leak in
Show answer
Answer: D. remove air and moisture (non-condensables) that leak in
Excessive purging can indicate a leak.
- Safety
10. When handling refrigerant, you should wear
- A. only a dust mask
- B. safety glasses and gloves
- C. nothing special
- D. sandals
Show answer
Answer: B. safety glasses and gloves
Liquid refrigerant can cause frostbite.
Get fresh questions every day, focused on your weak topics, plus timed mock tests. Free to start.
Practise free in the web app Practise on TelegramAbout the EPA 608 on Mock Night · Original practice questions; not affiliated with the exam board.