12,900+ practice questions · 144 exams · new questions added every week
Practice questions › NDT › Magnetic particle testing (MT)

NDT Magnetic particle testing (MT) practice questions

10 free questions with answers and explanations. Try each one, then tap “Show answer”.

  1. Properties

    1. Coercive force is

    • A. the field needed to start magnetising
    • B. the reverse field needed to remove residual magnetism
    • C. the weight a yoke can lift
    • D. the speed of particles
    Show answer

    Answer: B. the reverse field needed to remove residual magnetism

    Shown on the hysteresis loop.

  2. Techniques

    2. Which current is better for detecting surface-breaking defects?

    • A. AC
    • B. DC
    • C. No current
    • D. Both are useless
    Show answer

    Answer: A. AC

    AC concentrates the field near the surface (skin effect).

  3. Particles

    3. A mix of elongated and spherical dry particles is used because

    • A. elongated particles align with leakage fields and spherical ones flow easily
    • B. it reduces magnetism
    • C. it looks better
    • D. it is cheaper
    Show answer

    Answer: A. elongated particles align with leakage fields and spherical ones flow easily

    Both shape and size affect sensitivity.

  4. Technique

    4. For a fluorescent wet bath, the typical settled volume is

    • A. 10–20 mL per 100 mL
    • B. 0.1–0.4 mL per 100 mL
    • C. 0 mL
    • D. 1.2–2.4 mL per 100 mL
    Show answer

    Answer: B. 0.1–0.4 mL per 100 mL

    Visible (colour) baths settle at 1.2–2.4 mL per 100 mL.

  5. Related methods

    5. Magnetic flux leakage (MFL) is widely used to scan

    • A. concrete walls
    • B. plastic pipes
    • C. storage tank floors and pipelines for corrosion
    • D. wooden structures
    Show answer

    Answer: C. storage tank floors and pipelines for corrosion

    MFL uses the same leakage principle without particles.

  6. Interpretation

    6. A crack running parallel to the magnetic field will

    • A. give the strongest indication
    • B. likely be missed
    • C. always be detected
    • D. glow red
    Show answer

    Answer: B. likely be missed

    That is why two directions are tested.

  7. Techniques

    7. A known risk of using prods is

    • A. arc strikes that can damage the part
    • B. loss of couplant
    • C. corrosion from the developer
    • D. radiation exposure
    Show answer

    Answer: A. arc strikes that can damage the part

    Good contact and correct current reduce the risk.

  8. Properties

    8. Reluctance is

    • A. resistance to electric current
    • B. opposition to magnetic flux
    • C. light intensity
    • D. attraction of particles
    Show answer

    Answer: B. opposition to magnetic flux

    It is the magnetic equivalent of electrical resistance.

  9. Safety

    9. UV-A lamps used for fluorescent MT should

    • A. be used without filters for brightness
    • B. have intact filters to block harmful UV
    • C. only be used outdoors
    • D. be pointed at the eyes
    Show answer

    Answer: B. have intact filters to block harmful UV

    Damaged filters let through harmful short-wave UV.

  10. Particles

    10. Before using a wet fluorescent bath, it should also be checked for

    • A. radioactivity
    • B. hardness
    • C. salt content only
    • D. contamination and loss of fluorescence
    Show answer

    Answer: D. contamination and loss of fluorescence

    Compare against a reference standard.

Want more NDT Magnetic particle testing (MT) questions?

Get fresh questions every day, focused on your weak topics, plus timed mock tests. Free to start.

Practise free in the web app Practise on Telegram

More NDT practice

About the NDT on Mock Night · Original practice questions; not affiliated with the exam board.