  1. Calculations

    1. The dose rate is 160 µSv/h at 10 m from a gamma source. What is it at 40 m?

    • A. 20 µSv/h
    • B. 40 µSv/h
    • C. 10 µSv/h
    • D. 640 µSv/h
    Show answer

    Answer: C. 10 µSv/h

    Inverse square law: I₂ = I₁ × (d₁/d₂)² = 160 × (1/4)² = 10 µSv/h.

  2. Calculations

    2. Find the geometric unsharpness: source size 2 mm, object-to-film distance 20 mm, source-to-object distance 600 mm.

    • A. 0.6 mm
    • B. 0.067 mm
    • C. 0.065 mm
    • D. 0.037 mm
    Show answer

    Answer: B. 0.067 mm

    Ug = F × t ÷ D = 2 × 20 ÷ 600 = 0.067 mm.

  3. Calculations

    3. Find the geometric unsharpness: source size 3 mm, object-to-film distance 20 mm, source-to-object distance 700 mm.

    • A. 0.083 mm
    • B. 0.086 mm
    • C. 0.033 mm
    • D. 1.05 mm
    Show answer

    Answer: B. 0.086 mm

    Ug = F × t ÷ D = 3 × 20 ÷ 700 = 0.086 mm.

  4. Image

    4. On a radiograph, porosity usually appears

    • A. as a bright straight line
    • B. darker than the surrounding weld
    • C. invisible
    • D. lighter than the surrounding weld
    Show answer

    Answer: B. darker than the surrounding weld

    Less material means more radiation reaches the film.

  5. Image

    5. When the inside of a pipe cannot be reached, a common technique is

    • A. pulse-echo
    • B. single wall single image only
    • C. prod technique
    • D. double wall single image (DWSI)
    Show answer

    Answer: D. double wall single image (DWSI)

    Radiation passes through both walls; only the film-side wall is evaluated.

  6. Image

    6. A lead letter 'B' on the back of the cassette is used to

    • A. show the beam direction
    • B. mark the film batch
    • C. identify the welder
    • D. detect backscatter
    Show answer

    Answer: D. detect backscatter

    If a light 'B' appears, backscatter is too high.

  7. Calculations

    7. The dose rate is 120 µSv/h at 5 m from a gamma source. What is it at 10 m?

    • A. 33 µSv/h
    • B. 60 µSv/h
    • C. 240 µSv/h
    • D. 30 µSv/h
    Show answer

    Answer: D. 30 µSv/h

    Inverse square law: I₂ = I₁ × (d₁/d₂)² = 120 × (1/2)² = 30 µSv/h.

  8. Safety

    8. The international radiation warning sign is the

    • A. flame
    • B. skull and crossbones
    • C. exclamation mark
    • D. trefoil
    Show answer

    Answer: D. trefoil

    Used on barriers, containers and labels.

  9. Calculations

    9. An Ir-192 source (half-life about 74 days) has an activity of 60 Ci. Roughly what is its activity after 222 days?

    • A. 8.6 Ci
    • B. 30 Ci
    • C. 7.5 Ci
    • D. 3.75 Ci
    Show answer

    Answer: C. 7.5 Ci

    222 days is 3 half-lives: 60 ÷ 2^3 = 7.5 Ci.

  10. Calculations

    10. Find the geometric unsharpness: source size 4 mm, object-to-film distance 10 mm, source-to-object distance 700 mm.

    • A. 0.057 mm
    • B. 0.02 mm
    • C. 2.8 mm
    • D. 0.056 mm
    Show answer

    Answer: A. 0.057 mm

    Ug = F × t ÷ D = 4 × 10 ÷ 700 = 0.057 mm.