NDT Penetrant testing (PT) practice questions
10 free questions with answers and explanations. Try each one, then tap “Show answer”.
- Interpretation
1. Under ASME, a linear indication is one whose length is
- A. equal to its width
- B. less than its width
- C. more than three times its width
- D. more than 1 mm only
Show answer
Answer: C. more than three times its width
Otherwise it is a rounded indication.
- Cleaning
2. Vapour degreasing and solvent cleaning before PT are used to remove
- A. magnetism
- B. the base metal
- C. fluorescence
- D. oils and greases
Show answer
Answer: D. oils and greases
Contaminants stop penetrant entering defects.
- Process
3. Low part temperatures generally require
- A. no developer
- B. a longer penetrant dwell time
- C. a shorter dwell time
- D. fluorescent light only
Show answer
Answer: B. a longer penetrant dwell time
Penetrant becomes more viscous when cold.
- Materials
4. Fluorescent penetrant sensitivity levels run from ½ (lowest) to
- A. 100
- B. 2
- C. 10
- D. 4 (ultra-high)
Show answer
Answer: D. 4 (ultra-high)
Higher levels find finer cracks.
- Types
5. Which type of penetrant is generally more sensitive?
- A. Fluorescent
- B. Visible (red)
- C. Neither can find cracks
- D. Both are identical
Show answer
Answer: A. Fluorescent
Fluorescent indications glow under UV-A light.
- Principles
6. Penetrant testing relies mainly on
- A. sound reflection
- B. capillary action
- C. X-ray absorption
- D. magnetism
Show answer
Answer: B. capillary action
The penetrant is drawn into surface-breaking openings.
- Process
7. Under ASME Section V, the standard temperature range for PT is
- A. 20 °C to 30 °C only
- B. 0 °C to 100 °C
- C. -10 °C to 40 °C
- D. 10 °C to 52 °C
Show answer
Answer: D. 10 °C to 52 °C
Outside this range the procedure must be qualified.
- Materials
8. A lipophilic emulsifier is
- A. oil-based and applied after the penetrant dwell
- B. a cleaner used before penetrant
- C. a developer
- D. water-based remover
Show answer
Answer: A. oil-based and applied after the penetrant dwell
Hydrophilic removers are water-based.
- Materials
9. With post-emulsifiable penetrants, which time is most critical to control?
- A. Time to read the procedure
- B. Shelf life of the developer
- C. Emulsification time
- D. Drying time of the cleaner
Show answer
Answer: C. Emulsification time
Too long and penetrant is removed from defects.
- Process
10. If a part must be re-inspected, it should be
- A. wiped and inspected again
- B. magnetised
- C. fully cleaned and processed again from the start
- D. just given more developer
Show answer
Answer: C. fully cleaned and processed again from the start
Old penetrant in defects can give unreliable results.